Atwood 8940 Iii Dclp Troubleshooting

Atwood / Hydro Flame Furnace Model 8940-AC-III Tune-Up Kit comes in two variations. The first (Kit #1) has a single sense electrode (one wire that goes to the electrode), the second (Kit #2) has a dual sense electrode (two wires that go to the electrode). Please verify which kit is applicable to your furnace prior to ordering

Tune-Up Kit #1 (Single Sense Electrode):

Troubleshooting
  • Item #36 Sail Switch 36680 (31377)

Tune-Up Kit #2 (Dual Sense Electrode):

  • Item #36 Sail Switch 36680 (31377)

Click The Down Arrow To View Complete Exploded Parts View Links & Available Downloads

Item# 2 Thermostat, Brown 38452 NLA

Item# 2 Thermostat, White 38453

Item# 3 Duct Cover 31361

RV Make: Damon, RV Model: 4096, RV Year: 2004, Brand: Atwood furnace, Model Number: 8940-iii-dclp. November 18th, 2020. I have just perched a 2004 Damon 4096 motorhome. It has two top air and heat unites and one Atwood furnace. The top units are remote control. There is no thermostat for the furnace. How dose it work with the top units remote. Atwood / Hydro Flame Furnace Model 8940-AC-III Tune-Up Kit comes in two variations. The first (Kit #1) has a single sense electrode (one wire that goes to the electrode), the second (Kit #2) has a dual sense electrode (two wires that go to the electrode). Atwood Mobile Products HYDRO FLAME 8940, HYDRO FLAME 8935 User Manual. LITERATURE NUMBER MPD 31232. DCLP-III DCLP-III.

Item# 4 Duct Adapter, 4 Inch 31474

Item# 6 Orifice 31077

Item# 7 Combustion Air Wheel 33128

Item# 9 Motor Gasket 37713

Item# 10 Gas Valve 31159, AC Models Only, Before S/N 0657716

Item# 10 Gas Valve 38603, AC Models Only, After S/N 0657715

Item# 19 DSI Board Bracket 34541

Atwood 8940 Iii Dclp Troubleshooting

Item# 20 Slide Plate 37442 After S/N 0657715

Atwood 8940-iii-dclp service manual

Item# 21 Circuit Breaker 35791, 5 Amp

Item# 22 Screw Latch 33847

Item# 23 DSI Module Board (24VAC Ignition Board) 37515

*Not Shown* Wiring Harness Kit 30232

Item# 27 Blower Housing

Item# 34 Motor Kit, AC Voltage 30132 (Replaces P# 35122)

Item# 36 Sail Switch 36680

Item# 37 Draft Cap (Exhaust) 38141

Atwood 8940-iii-dclp Troubleshooting

Item# 42 Capacitor 34039

Item# 45 Exhaust Wall Gasket 37956

Item# 50 Blower Wheel 34099

Item# 51 Electrode (Single Sense) 34570

*Not Shown* Single Sense Electrode Gasket 37100

Item# 51 Electrode (Dual Sense) 36997

*Not Shown* Dual Sense Electrode Gasket 32172

Item# 52 Limit Switch 37021

Item# 53 Burner Assembly 35491

Item# 55 Blower Assembly 34014

Item# 58 Transformer 35121

Item# 60 Igniter Lead 34571

Available Downloads:

Sep 1, The edition of the Atwood Furnace Service Manual is a resource . II Directional Air Box Insert.

Wiring Diagram for II / II. Page 1.

LITERATURE NUMBER MPD hydro flame ® III Series Furnace MODELS , Technical Installation Manual ENGLISH, FRANCAIS. Sep 16, Need wiring diagram for atwood model #dclp motor # - Answered by a verified RV Mechanic.

I am trying to replace a furnace for my Mom and she has a III DCLP and I am looking at a IV Need the wire diagram for the time delay switch on the atwood .

Show wiring diagram for fa series hydro flame rv furnance. DCLP-.

DCLP-III. *(W.C. = Water Column).

Atwood 8940-iii-dclp Manual

ACLC-II. ACLC-IH.

40, .. make electrical connections: see WIRING DIAGRAM FIG 5.

1.atwood mobile products hydro flame user manual this instruction manual is for use by an authorized service technician to install an atwood - hydro flame. tm. furnace.

Atwood

installer: leave this manual with appliance. dc wiring diagrams..

Atwood 8940-iii-dclp Parts Diagram

5. illustrations.

Atwood Mobile Products Furnace User Manual. Open as PDF. AC & DC WIRING DIAGRAMS ..

5. ILLUSTRATIONS Looking for a owneroperator manual for a Atwood Mobile I have iv furnace which want light blower com.

Nov 16, · Atwood III-dclp: I am getting the 3 flashes on the circuit board indicating an ignition lockout fault. Originally the blower would start, the furnace would ignite temporarily, then shut off after a few seconds, repeat this 3 times and then the blower would turn off.4/5.

The furnace must be installed so electrical components are protected from water.

To make electrical connections see WIRING DIAGRAM FIG 5. 3 1.

Atwood Model 8940-iii-dclp Parts

Route wiring to left side of furnace. 2. Remove junction box cover.

3. Connect white wire to furnace white wire.

4. .

Need wiring diagram for atwood model #dclp motor # - Answered by a verified RV Mechanic We have an III-dclp furnace serial #(NNN) NNN-NNNNwith a new atwood dsi board and the furnace will light, run about 5 seconds, shut down retry 2 more times and flash a 3 red light code.Atwood Mobile Products HYDRO FLAME user manual - wiringall.com - Solve your problemAtwood Mobile Products Furnace User Guide | wiringall.com